Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Microbiol Spectr ; : e0396223, 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38652098

RESUMO

Water contamination in dental unit waterlines (DUWLs) is a potential source of healthcare-associated infection during dental care. The aim of this study was to evaluate the microbiological quality of DUWLs water from newly installed dental chairs in a French University Hospital. The microbiological quality of water from 24 new DUWLs initially disinfected by ICX Renew-prior to use of the dental units for patient treatment-was assessed for total culturable aerobic bacteria at 22°C and 36°C, Legionella sp., Pseudomonas aeruginosa, and total coliforms. Among the 24 samples analyzed, 21 were compliant with the water quality levels: 19 had no bacteria, and 2 contained only 4 and 1 CFU/mL for total culturable aerobic bacteria at 22°C and 36°C, respectively. Three samples were non-compliant due to contamination by P. aeruginosa (4, 2, and 2 CFU/100 mL). Controlling and preventing the microbiological contamination of DUWLs, especially by pathogenic bacteria, at the time of the installation of the new dental chairs are crucial to prevent healthcare-associated infection in dentistry. IMPORTANCE: Dental unit waterlines (DUWLs) of new dental chairs may be contaminated before their first clinical use, so an initial shock disinfection is crucial at the time of their installation. The microbiological analyses are crucial to control the water quality of DUWLs before their first clinical use because their disinfection does not guarantee the elimination of all bacteria.

2.
Euro Surveill ; 29(14)2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38577805

RESUMO

In 2019-2022, a prolonged outbreak of oxacillinase (OXA)-48-producing Citrobacter farmeri due to a persistent environmental contamination, occurred in our haematology intensive care unit. In April 2019, we isolated OXA-48-producing C. farmeri from rectal samples of two patients in weekly screenings. The cases had stayed in the same hospital room but 4 months apart. We screened five patients who had stayed in this room between the two cases and identified a third case. Over the following 3 years, five other cases were detected, the last case in September 2022. In total, eight cases were detected: seven colonised with the bacterium and one infected with a lethal outcome. All cases stayed in the same hospital room. We detected OXA-48-producing C. farmeri from a shower, washbasin drains and wastewater drainage of the bathroom of the hospital room. Molecular typing confirmed that all C. farmeri isolates from the environment and the cases were indistinguishable. Despite bundle measures to control the outbreak, the bacterium persisted in the system, which resulted in transmission to new patients. A design defect in the placement of wastewater drains contributed to the persistence and proliferation of the bacterium. The room was closed after the last case and the bathroom rebuilt.


Assuntos
Citrobacter , Infecção Hospitalar , Águas Residuárias , Humanos , Infecção Hospitalar/microbiologia , beta-Lactamases , Proteínas de Bactérias/genética , Surtos de Doenças , Hospitais , Cuidados Críticos , Klebsiella pneumoniae
3.
Int J Med Inform ; 186: 105419, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38513323

RESUMO

BACKGROUND: Electronic surveillance software (ESS) collects multiple patient data from hospital software to assist infection control professionals in the prevention and control of hospital-associated infections. This study aimed to understand the perceptions of end users (i.e., infection control professionals) and the facilitators and barriers related to a commercial ESS named ZINC and to assess its usability. METHODS: A mixed-method research approach was adopted among infection control professionals 10 months after the implementation of commercial ESS in the university hospital of Nancy, France. A qualitative analysis based on individual semistructured interviews was conducted to collect professionals' perceptions of ESS and to understand barriers and facilitators. Qualitative data were systematically coded and thematically analyzed. A quantitative analysis was performed using the System Usability Scale (SUS). RESULTS: Thirteen infection control professionals were included. Qualitative analysis revealed technical, organizational and human barriers to the installation and use stages and five significant facilitators: the relevant design of the ESS, the improvement of infection prevention and control practices, the designation of a champion/superuser among professionals, training, and collaboration with the developer team. Quantitative analysis indicated that the evaluated ESS was a "good" system in terms of perceived ease of use, with an overall median SUS score of 85/100. CONCLUSIONS: This study shows the value of ESS to support inpatient infections as perceived by infection control professionals. It reveals barriers and facilitators to the implementation and adoption of ESS. These barriers and facilitators should be considered to facilitate the installation of the software in other hospitals.


Assuntos
Infecção Hospitalar , Pacientes Internados , Humanos , Pesquisa Qualitativa , Controle de Infecções , Infecção Hospitalar/prevenção & controle , Eletrônica
4.
Infect Dis Now ; 53(6): 104724, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37209829

RESUMO

OBJECTIVE: To quickly implement Infection Prevention and Control measures ("search and isolate" strategy), a computerized monitoring system for carbapenemase-producing Enterobacteriaceae (CPE) and Vancomycin-resistant Enterococcus faecium (VRE) carrier and contact patients has been developed in our hospital since 2014. The objectives were to assess the value of a computerized monitoring system in CPE and VRE management and to evaluate the relevance of extended monitoring of all contact patients. METHODS: Using the data extracted from the computerized system, we conducted a descriptive analysis of CPE and VRE carriers detected from 2004 to 2019 and CPE and VRE extensive contact patients (when hospital stay overlapped with the stay of a carrier in the same unit) from 2014 to 2019. RESULTS: Between 2015 and 2019 (microbiological data only available during this period), 113 CPE and 558 VRE carriers were registered in the database (DB). Among them, 33.9% CPE and 12.8% VRE carriers were infected (p = 0.02). The most frequent infections were urinary tract infections (52.0%), bloodstream infections (20.0%) and pneumonia (16.0%). Close to 8000 (7679) extended contact patients were exposed. Only 26.2% of them were removed from the DB because of appropriate negative post-exposure rectal screenings. No rectal screening was performed in 33.5% of contact patients. Between 2014 and 2019, 16 outbreaks occurred. The proportion of infected carriers differed significantly between outbreaks (index cases) and non-epidemic episodes (50.0% and 20.5% respectively, p = 0.03). The detection system was able to control diffusion in 99.7% of readmissions of known carriers. Among the 360 readmissions detected by the system, only one was involved in an outbreak due to non-compliance with infection control measures. CONCLUSION: Given the low screening completion rate (26.2%) and the low detection rate (1.3%), extended monitoring of contact patients does not seem relevant. After five years of use, the computerized monitoring system has demonstrated its effectiveness in terms of responsiveness and limitation of the spread of multidrug-resistant organisms.


Assuntos
Enterobacteriáceas Resistentes a Carbapenêmicos , Enterococcus faecium , Infecções por Bactérias Gram-Positivas , Enterococos Resistentes à Vancomicina , Humanos , Vancomicina , Infecções por Bactérias Gram-Positivas/tratamento farmacológico , Infecções por Bactérias Gram-Positivas/epidemiologia , Infecções por Bactérias Gram-Positivas/prevenção & controle
5.
BMJ Open ; 12(4): e056125, 2022 04 05.
Artigo em Inglês | MEDLINE | ID: mdl-35383069

RESUMO

INTRODUCTION: Antibiotic resistance is one of the most pressing health threats that mankind faces now and in the coming decades. Antibiotic resistance leads to longer hospital stays, higher medical costs and increased mortality. In order to tackle antibiotic resistance, we will implement in our tertiary care university hospital a computerised-decision support system (CDSS) facilitating antibiotic stewardship and an electronic surveillance software (ESS) facilitating infection prevention and control activities. We describe the protocol to evaluate the impact of the CDSS/ESS combination in adult inpatients. METHODS AND ANALYSIS: We conduct a pragmatic, prospective, single-centre, before-after uncontrolled study with an interrupted time-series analysis 12 months before and 12 months after the introduction of the CDSS for antibiotic stewardship (APSS) and ESS for infection surveillance (ZINC). APSS and ZINC will assist, respectively, the antibiotic stewardship and the infection prevention and control teams of Nancy University Hospital (France). We will evaluate the impact of the CDSS/ESS on the antibiotic use in adult (≥18 years) inpatients (hospitalised ≥48 hours). The primary outcome is the prescription rate by all healthcare professionals from the hospital of all systemic antibiotics expressed in defined daily doses/1000 patients/month. Concurrently, we will assess the safety of the intervention, its impact on the appropriateness of antibiotic prescriptions and on additional precautions (isolation precautions) as recommended in guidelines, and on bacterial epidemiology (multidrug-resistant bacteria and Clostridioides difficile infections) in the hospital. Finally, we will evaluate the users' satisfaction and the cost of this intervention from the hospital perspective. ETHICS AND DISSEMINATION: The protocol has been approved by the Ethics Committee of Nancy University Hospital and registered on the ClinicalTrials platform. Results will be disseminated through conferences' presentations and publications in peer-reviewed journals. TRIAL REGISTRATION NUMBER: NCT04976829.


Assuntos
Gestão de Antimicrobianos , Adulto , Antibacterianos/uso terapêutico , Gestão de Antimicrobianos/métodos , Computadores , Atenção à Saúde , Humanos , Análise de Séries Temporais Interrompida , Estudos Prospectivos
6.
Artigo em Inglês | MEDLINE | ID: mdl-32290533

RESUMO

Biofilms in dental unit waterlines (DUWL) are a potentially significant source of contamination posing a significant health risk as these may come into contact with patients and dental staff during treatment. The aim of this study was to evaluate the microbiological quality of DUWL water treated by Biofilm-Removing-System® (BRS®) and Alpron®/Bilpron® disinfectant solutions for six years in a French university hospital. The microbiological quality of water supplied by 68 dental units-initially shock treated with BRS®, then continuously treated by Alpron® with sterile water during working days and Bilpron® during inactivity period, and combined with purging every morning and after each patient-was assessed biannually during six years for total culturable aerobic bacteria at 22 °C and 36 °C, Legionella sp., Pseudomonas aeruginosa, and total coliforms. A total of 628 samples were analyzed, 99.8% were compliant with extended microbiological levels, and we never detected pathogen bacteria like Legionella sp. and P. aeruginosa. Only one sample (0.2%) was noncompliant with the level of total culturable aerobic bacteria at 36 °C, which exceeded 140 colony forming units per mL. The protocol implemented in our university hospital gives excellent results and enables control of the microbiological quality of DUWL water in the long term.


Assuntos
Biofilmes , Equipamentos Odontológicos , Desinfetantes , Ácido Edético , Hipoclorito de Sódio , Contagem de Colônia Microbiana , Desinfetantes de Equipamento Odontológico , Desinfetantes/farmacologia , Ácido Edético/farmacologia , Contaminação de Equipamentos , Humanos , Hipoclorito de Sódio/farmacologia , Microbiologia da Água
7.
Artigo em Inglês | MEDLINE | ID: mdl-31683783

RESUMO

Water is essential during dental care. Physical and chemical techniques should be used to maintain a good water quality with respect to bacteria, and to ensure the safety of exposed patients and dental staff. The aim of this survey was to assess the modalities used by dental practitioners in Eastern France to maintain the water quality of their dental unit waterlines (DUWLs). A questionnaire about water quality maintenance practices was sent to 870 dental offices in 2016. The questionnaires were completed by 153 dental offices, covering about 223 dental care units. The majority of units were fed by mains water (91.0%), which is generally unfiltered (71.3%). One-third (33.6%) of the units had an independent water bottle reservoir. Flushing, a basic physical technique to improve the quality of units' outflow water, was practiced in 65.4% of dental offices. Concerning the chemical treatment of water, it was used for 62.1% of the units. An analysis of the microbiological quality of the DUWL water was only carried out in 2.6% of the offices. In conclusion, providing better training to dental staff seems necessary to improve their practices and to generalize procedures that improve the microbiological quality of the water used.


Assuntos
Biofilmes , Contagem de Colônia Microbiana , Desinfetantes de Equipamento Odontológico , Equipamentos Odontológicos/microbiologia , Contaminação de Equipamentos/prevenção & controle , Controle de Infecções Dentárias/métodos , Microbiologia da Água , França , Humanos , Inquéritos e Questionários
8.
Am J Infect Control ; 44(9): 1061-2, 2016 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-27086907

RESUMO

Waterborne pathogens, such Legionella pneumophila and Pseudomonas aeruginosa, are major contributors to hospital-associated infection. Point-of-use water filtration has demonstrated benefits to prevent infection implicating waterborne pathogens. Despite the quality of the filters, misuse may expose patients to these pathogens.


Assuntos
Infecção Hospitalar/prevenção & controle , Filtração/métodos , Doença dos Legionários/prevenção & controle , Sistemas Automatizados de Assistência Junto ao Leito , Infecções por Pseudomonas/prevenção & controle , Propriedades de Superfície , Microbiologia da Água , Humanos , Legionella pneumophila/isolamento & purificação , Pseudomonas aeruginosa/isolamento & purificação
9.
Am J Infect Control ; 44(2): 247-9, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26455869

RESUMO

A water quality study of dental units showed biofilm and opportunistic microorganisms. We report the steps that ultimately allowed us to obtain water quality as water for standard care with no pathogens throughout all dental units. In summary, treatment with continuous disinfection associated with use of sterile water allowed us to restore the water quality at the output of dental care units while ensuring the safety of care.


Assuntos
Bactérias/crescimento & desenvolvimento , Biofilmes/crescimento & desenvolvimento , Desinfecção/métodos , Microbiologia da Água , Água/normas , Assistência Odontológica/normas , Instituições Odontológicas , Humanos , Qualidade da Água
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...